Path: Top > S1-Final_Project > Fakultas_Teknik_dan_Ilmu_Komputer > Teknik_Komputer/Sistem Komputer > 2012

Otomatisasi Metode Impressed Current Cathodic Protection (ICCP) Pada Logam Berbasis Mikrokontroler ATMEGA 16

Undergraduate Theses from JBPTUNIKOMPP / 2013-01-30 10:42:10
By : Cecep Wiliam NIM. 10207701, Perpustakaan UNIKOM (cepwil@gmail.com)
Created : 2013-01-30, with 15 files

Keyword : Pengendalian Korosi, Impressed Current Cathodic Protection, Buck- Boost Converter, Data Acquisition, Monitoring Sistem
Url : http://alumni.unikom.ac.id

Salah satu masalah utama untuk peralatan dan struktur bahan yang terbuat dari logam adalah korosi yang mengikis struktur pada logam sampai pada taraf yang sangat merusak. Korosi adalah kerusakan atau degradasi logam akibat adanya reaksi oksidasi-reduksi antara suatu logam dengan berbagai zat di lingkungannya dan menghasilkan residu yang tidak dikehendaki yang disebut dengan karat. Karena sifatnya yang merusak, korosi menjadi suatu permasalahan yang serius dan sangat penting sehingga menjadi perhatian industri-industri di dunia. Sistem dibuat untuk mengendalikan arus proteksi pada logam supaya tetap berada pada kriteria proteksi katodik yaitu antara 0.850 V sampai 1.5 V (dalam nilai absolut) terhadap elektroda referensi Ag/AgCl. Sistem proteksi katodik arus paksa kemudian diimplementasikan pada logam baja dengan ukuran 10 x 10 x 0,2 cm sebagai logam yang akan diproteksi dan ditempatkan pada lingkungan uji. Program Data Acquisition and Monitoring pada PC akan langsung berjalan ketika tombol Mulai ditekan, dan langsung memantau kondisi sistem, melakukan pengambilan data setiap sepuluh menit sekali yang kemudian disimpan ke dalam database secara otomatis, dan setiap satu hari sampai satu bulan sekali dapat dilakukan backup data untuk analisa. Buck-Boost Converter berperan sebagai aktuator yang dikendalikan dengan memberikan sinyal PWM dari mikrokontroler untuk proses switching, semakin besar duty cycle PWM yang diberikan, maka arus dan tegangan keluaran dari Buck-Boost Converter pun akan semakin besar, dan semakin besar arus dan tegangan yang diberikan pada logam, maka tegangan Ei akan semakin kecil. Kebutuhan arus logam uji adalah sebesar 3 mA yang diketahui melalui uji kebutuhan arus, sehingga arus sebesar 6,292 mA pada lingkungan air ledeng, 5,493 mA pada lingkungan air laut, 5,951 mA pada lingkungan air cuka, dan 5,694 mA pada lingkungan air kapur yang diberikan saat pengujian sistem dapat melindungi struktur logam uji dari proses korosi karena terpenuhinya kebutuhan elektron dan masih berada dalam range kriteria proteksi katodik.

Description Alternative :

One of the main problems for structures made of metallic material is corrosion that erodes the structure of the metal to the extent that is very damaging. Corrosion is the destruction or degradation of metal due to the oxidation-reduction reaction between a metal with a variety of substances in the environtment and produce an undesirable residues called rust. Because of its destructiveness, corrosion becomes a serious problem and it is very important so that became the attention of industries in the world. System designed to control the current protection to the metal in order to maintain current to remain on the cathodic protection criteria between 0,850 V to 1,5 V (in absolut value) agains reference electrode Ag/AgCl. Impressed Current Cathodic Protection then implemented to the steel metal with size 10 x 10 x 0,2 cm as the metal to be protected and then placed in the testing environments. Data Acquisition and Monitoring Program on the PC will automatically run when the Mulai button is pressed and immediately begin to monitor the condition of the system, perform data collection every ten minutes which is then stored into the database automatically, and every single day to once a month to do data backups for analysis. Buck-Boost Converter act as actuators which is controlled by providing a PWM signal from the microcontroller for the switching process, the greater the PWM duty cycle is given, then the output current and output voltage of the Buck-Boost Converter would be even greater, and the greater the current and voltage applied to the metal, then the Ei voltage will be smaller. Current requirement for testing metal is 3 mA known through current requirement test, so that a current of 6,292 mA in tap water environments, 5,493 mA in the seawater environments, 5,951 mA in the vinegar environtment, and 5,694 mA in the limewater environtment which is given when testing system can protect testing metal structure from corrosion process due to fulfillment of the electron needs and is still in the range of cathodic protection criteria.

Give Comment ?#(0) | Bookmark

PropertyValue
Publisher IDJBPTUNIKOMPP
OrganizationP
Contact Namedyah@unikom.ac.id
AddressJl. Dipati Ukur No.116 Lt.7
CityBandung
RegionWest Java
CountryIndonesia
Phone022-2533825 ext.112
Fax022-2533754
Administrator E-mailperpus@unikom.ac.id
CKO E-mailperpus@unikom.ac.id